UK Heat Pump Glossary
Every term you'll encounter in a UK heat pump quote, install, or guide โ explained in plain English by an MCS engineer. Bookmark it before you compare quotes.
A
Air source heat pump (ASHP) โ Heat pump that extracts heat from outside air. Most common UK type. See ASHP vs GSHP.
Anti-vibration mounts โ Rubber feet between outdoor unit and concrete base. Cut noise/vibration transmission by 8-12 dB.
Article 4 Direction โ Planning rule that removes Permitted Development rights for specific zones. Common in central London, Bath, Edinburgh New Town. See Planning Permission.
B
BS EN 12831 โ UK standard for heat loss calculation. Required for MCS heat pump design.
BS EN 14825 โ UK standard for measuring SCOP in a controlled environment.
BUS (Boiler Upgrade Scheme) โ England's ยฃ7,500 heat pump grant. See BUS Guide.
BTU (British Thermal Unit) โ Imperial unit for heat output, often used for radiator capacity. 3,412 BTU = 1 kW.
C
Cap (Ofgem price cap) โ Maximum unit rate suppliers can charge default-tariff customers. Updated quarterly.
Cavity wall โ Two-leaf brick wall with air gap. Standard UK construction 1930-present. Can be insulated.
COP (Coefficient of Performance) โ Heat output รท electricity input at a single operating point. Manufacturers cherry-pick favourable conditions; always compare SCOP instead.
Compressor โ Pump that circulates and pressurises the refrigerant. The most expensive component to replace.
Condensate โ Water that drips off the heat pump's evaporator coil during operation. Needs a drain (and frost protection in winter).
Conservation Area โ Planning designation protecting historic neighbourhoods. May limit external heat pump siting.
Cylinder โ Insulated tank storing hot water for taps and showers. Heat pumps usually need a 200-300L unvented cylinder.
D
DHW (Domestic Hot Water) โ Hot water for taps, showers, baths. Separate from heating water.
Defrost cycle โ Brief reverse cycle where heat pump melts ice from its outdoor coil in winter. Normal, lasts 5-10 minutes.
Design outdoor temperature โ Coldest temperature your heat pump is sized to handle. -2ยฐC London, -5ยฐC Edinburgh, -7ยฐC Highlands.
Design flow temperature โ Target water temperature leaving the heat pump at design outdoor temp. Lower = higher SCOP. UK targets 35-50ยฐC ideal.
DESNZ (Department for Energy Security and Net Zero) โ UK government department running BUS, F-Gas, Future Homes Standard.
E
EPC (Energy Performance Certificate) โ UK home energy rating A-G. Most grants require an in-date EPC.
Evaporator โ Outdoor unit coil that absorbs heat from air.
ECO (Energy Company Obligation) โ UK scheme requiring energy suppliers to fund energy efficiency for low-income households. Limited heat pump scope.
F
F-Gas โ Fluorinated greenhouse gases used as refrigerants. UK F-Gas Regulation requires Cat 1 or Cat 2 certified engineers. See F-Gas Rules UK.
Flare joint โ Field-made refrigerant connection (vs factory-brazed). Higher leak risk if poorly made.
Flow temperature โ Water temperature leaving the heat pump to radiators/UFH. Lower is better for efficiency.
Future Homes Standard โ UK rule (late 2025) requiring new build emissions 75-80% below 2013 baseline. Effectively bans gas boilers in new builds.
G
Gas Safe โ UK certification for gas-related work. Different from F-Gas (which is for refrigerants).
GSHP (Ground source heat pump) โ Heat pump using buried coils to extract heat from ground. Higher SCOP than ASHP but more expensive install. See ASHP vs GSHP.
GWP (Global Warming Potential) โ Climate impact of a refrigerant vs COโ. Lower = better. R290 = 3, R32 = 675, R410A = 2,088.
H
Heat battery โ Compact thermal store using phase-change material (Sunamp, Tepeo). Alternative to cylinder. See Heat Battery vs Cylinder.
Heat loss calculation โ Room-by-room assessment per BS EN 12831. Required for proper sizing.
Heritage statement โ Document describing impact on a listed building. Required for Listed Building Consent.
HES (Home Energy Scotland) โ Scottish heat pump grant + interest-free loan scheme. See HES Guide.
HIES (Home Insulation and Energy Systems) โ UK consumer-protection scheme covering MCS installers.
Hybrid heat pump โ Heat pump paired with gas boiler. Boiler covers peak demand. See Hybrid Worth It.
I-K
Immersion heater โ Electric backup element in the cylinder. Used for weekly Legionella cycle or emergency heating.
Inverter โ Electronic control that varies compressor speed. Modern heat pumps modulate output 25-100% via inverter.
K2 / K3 radiator โ Double or triple-panel radiator with higher heat output at low flow temperature. Common in heat pump retrofits.
kW (kilowatt) โ Unit of heat output. 1 kW = 3,412 BTU. UK heat pumps typically 5-15 kW.
kWh (kilowatt-hour) โ Unit of energy. 1 kWh = 1 kW for 1 hour. UK home heating typically 8,000-15,000 kWh/yr.
L
LBC (Listed Building Consent) โ Formal permission required for any alteration to a listed building. Free, 8-week target. See Listed Buildings.
Legionella cycle โ Weekly heating of cylinder to 60ยฐC+ to prevent bacterial growth.
Lockshield valve โ Adjustable radiator valve used for balancing flow during commissioning.
Lw (sound power) โ Total acoustic energy emitted by unit. Manufacturer rating.
Lp (sound pressure) โ What you hear at distance. Lp drops ~6 dB per doubling of distance.
M-N
MCS (Microgeneration Certification Scheme) โ UK quality mark for renewables. Required for BUS grant. See MCS Explained.
MELCloud / MELCare โ Mitsubishi heat pump app and cover plan.
Microbore โ 8-10mm copper pipework (1970s-90s common). Often too narrow for heat pumps.
MIS 3005 โ MCS install standard for heat pumps.
MIS 020 โ MCS noise standard (42 dB(A) at 1m from neighbour window).
MVHR (Mechanical Ventilation with Heat Recovery) โ Whole-house ventilation system common in new builds. Reduces peak heat loss.
O-P
Onecta โ Daikin heat pump app.
Octopus Cosy โ Heat-pump-targeted half-hourly tariff with 3 daily cheap windows. See Cosy vs Standard.
Ofgem โ UK energy regulator setting price cap.
PCM (Phase Change Material) โ Substance that absorbs heat by melting. Used in heat batteries.
Permitted Development โ Right to install heat pump without planning permission (most UK homes since May 2025 reform).
Primary system โ The water loop between heat pump and emitters (radiators/UFH).
Q-R
QANW (Quality Assured National Warranties) โ MCS consumer-protection scheme.
R290 โ Propane refrigerant. GWP 3. Preferred 2026 choice. Mildly flammable; siting rules apply.
R32 โ Difluoromethane refrigerant. GWP 675. Still legal but gradually restricted.
R410A โ Older refrigerant. GWP 2,088. Banned for new installs from 2020.
Recharge โ Adding refrigerant after a leak. Must be done by F-Gas engineer.
RECC (Renewable Energy Consumer Code) โ MCS consumer-protection scheme. Trading Standards-approved.
Refcom โ UK F-Gas company registration body.
Rural Uplift โ ยฃ1,500 extra Scottish grant for qualifying rural postcodes.
S
SCOP (Seasonal Coefficient of Performance) โ Average COP across a heating season. The most important number. See SCOP Explained.
sensoApp / sensoComfort โ Vaillant heat pump app and controller.
SMETS2 โ Smart Meter Equipment Technical Specifications v2. Standard UK smart meter, required for half-hourly tariffs.
Solid wall โ Single-leaf brick or stone wall (no cavity). Common pre-1930. Higher heat loss.
Standby loss โ Heat lost by cylinder/heat battery while sitting full. Cylinder: 1.5-2.0 kWh/day; heat battery: 0.3-0.7 kWh/day.
T-U
T-Cap (True Capacity) โ Panasonic technology holding rated output to -15ยฐC.
Tariff โ Energy price plan. Heat pumps benefit from half-hourly tariffs like Octopus Cosy.
Trace tape โ Self-regulating electric heater wrapped around condensate pipe to prevent freezing.
TRV (Thermostatic Radiator Valve) โ Self-regulating valve per radiator. Can hurt heat pump efficiency if cycling too aggressively.
UFH (Underfloor Heating) โ Low-temperature heating coils in floor build-up. Highest SCOP combination with heat pumps. See UFH + Heat Pump.
Unvented cylinder โ Pressurised cylinder delivering hot water at mains pressure.
U-value โ Heat loss rate of a wall, roof, or window. Lower is better. Modern new build wall U = 0.18 W/mยฒK; Victorian = 1.7-2.1.
V-Z
Vapour compression cycle โ Thermodynamic cycle (compressor, condenser, expansion valve, evaporator) underlying all heat pumps.
Warmer Homes Scotland โ Scottish low-income full-coverage energy efficiency scheme.
Weather compensation โ Control feature that adjusts flow temperature based on outdoor temperature. Adds 0.2-0.4 SCOP for free.
Workmanship warranty โ Cover via HIES/RECC/QANW. 2-6 years from MCS install. Separate from manufacturer warranty.